Trentham Energy

Fronius: restart the system

A restart clears most communication faults. Do the steps in order, and pick the video that matches your battery.

Rather watch? Jump to the videos

GEN24, with or without a Reserva battery

  1. Turn off the AC switch. It is next to the inverter, or in the switchboard labelled solar supply main switch or main switch inverter supply.
  2. Turn the DC switch on the front of the inverter left, to 0.
  3. Wait 1 to 2 minutes until the lights go off.
  4. With a Reserva: flick down the DC switch on the left of the battery, on every tower. Check all lights are off.
  5. Back on, in reverse. Reserva first: switch up, then press the start button once. Then the inverter DC switch to 1, then the AC switch on.

With a BYD battery

  1. Follow the Fronius BYD video from 1:33. Fronius says this order is for BYD HVM and HVS. It does not apply to HVS+, HVM+ or HVB.

Restart a GEN24 or GEN24 Plus

Video by Fronius

Restart a GEN24 Plus and Reserva battery

Video by Fronius

Restart a GEN24 with a BYD battery

Video by Fronius

Restart an older Primo or Symo

Video by Fronius

Still stuck?

Call the team on 1300 3458 00. If you can smell burning, or see damage or water on the system, don't touch it, call us.